International Masonry Institute
- Technical Support
- 1-800-IMI-0988
- Training
- 1-800-JOBS-IMI
Masonry Details
Full Details list
- 01.101: Foundation detail w/ termination bar
- 01.102: Foundation detail w/ cavity insert
- 01.103: Foundation detail w/ cavity insert & term. bar
- 01.201: Sill detail
- 01.201.2D: Sill Detail
- 01.202: Sill detail Interior
- 01.301: Head detail: steel lintel & bond beam
- 01.302: Head detail: steel lintel & bond beam w/ cavity insert
- 01.303: Head detail: steel lintel w/ double angle
- 01.304: Head detail: plate welded to I-beam
- 01.401: Window jamb & sills
- 01.401.2D: Window Jamb Detail
- 01.501: Shelf angle: typical face brick
- 01.501.2D: Shelf angle: typical face brick
- 01.502: Shelf angle w/ lipped brick
- 01.502.2D: Shelf angle w/ lipped brick
- 01.503: Shelf angle: typical face brick w/ termination bar
- 01.503.2D: Shelf angle: typical face brick w/ termination bar
- 01.601: Architectural effect: projected soldier course
- 01.701: Roof detail: metal cropping at parapet
- 01.703: Roof detail: low parapet
- 01.704: Roof detail: low roof - high wall
- 01.801: Movement joint in brick & block cavity wall
- 02.101: Foundation detail w/ termination bar
- 02.102: Foundation detail w/ termination bar & cavity insert
- 02.103: Foundation detail w/ termination bar, cavity insert & below grade brick
- 02.201: Sill detail
- 02.401: Window jamb detail
- 03.01: Flashing drip edge w/ enlarged detail
- 03.151: Grout Mold
- 03.161: Block Cleanout
- 03.163: Block Cleanout
- 03.164: Block Cleanout
- 03.501: Floor detail: concrete floor connection
- 03.502: Floor detail: CMU firewall, top of wall
- 03.802A: Control joint
- 03.802B: Control joint
- 03.802C: Fire rated control joint
- 03.811: Isolation joint
- 03.904: Load bearing pilaster
- 06.01: Brick veneer, wood studs
- 09.01: Floor Tile Expansion Joint
- 09.02: Floor Tile Expansion Joint over Concrete Control Joint
- 09.03: Floor Tile over CBU on Wood Subfloor
- 09.04: Floor Tile w/ Cement Mortar on Wood Subfloor
- 09.05: Floor Tile w/ Cement Mortar on Concrete
- 09.06: Floor Tile - Thinset on Concrete or Cured Mortar Bed
- 09.07: Floor Tile - Thinset on concrete
- 09.08: Floor Tile over CBU and Cork on Concrete
- 09.09: Wall Tile - One coat method, wet area
- 09.10: Wall Tile - One coat method, non-wet area
- 09.11: Wall Tile - Cement Mortar
- 09.12: Wall Tile - Thinset or mastic on CBU over steel studs
- 09.13: Floor Tile over CBU on Concrete
- 09.14: Wall Tile - Thinset on Concrete Masonry
- 09.15: Wall and Floor Tile - Thinset, corner condition
- 10.02: Flowable cement terrazzo
- 11.10: Allowable variations in mortar joint thickness
- 11.100: AAC exterior wall types
- 12.101: Corner detail
- 15.102: Stucco assembly: sheathed construction, wood framing
- 15.03: Stucco assembly: sheathed construction, steel framing
- 15.04: Stucco assembly: sheathed construction, direct applied to concrete masonry
- 15.05: Stucco assembly: sheathed construction, attached to concrete masonry
- 15.06: Stucco assembly: skim coat direct applied to concrete
- 15.07: Stucco assembly: two-coat stucco direct to concrete
- 15.08: Stucco assembly: attached to concrete
- 15.09: Stucco assembly: over CMU w/ insulation
- 19.101: Injected foam insulation
- 20.C1: Column connection detail: option 1
- 20.C2: Column connection detail: option2
- 20.P01: Plank at bearing wall
- 20.P02: Plank at bearing wall -- top of wall
- 20.P03: Plank at bearing wall -- interior wall; intermediate level
- 20.P04: Plank at bearing wall -- interior wall; top of wall
- 20.P14: Wall intersection
- 20.P15A: Bond beam plan - intersecting walls
- 20.P15B: Bond beam plan - corner condition