02.010.1301: Control Joint – Preformed Gasket

02.010.1301: Control Joint – Preformed Gasket This detail shows specially shaped sash block being used at the vertical control joint, to allow for insertion of a preformed gasket. The gasket is a rigid material, allowing in-plane shrinkage of the block, while providing some resistance to lateral loads. There is horizontal joint reinforcement at 16″ o.c.…

02.010.0313: Base of Wall – Single Wythe Block, Proprietary Flashing/Weeps

02.010.0313: Base of Wall – Single Wythe Block, Proprietary Flashing/Weeps This detail shows an 8” (nominal) split face concrete masonry (CMU) wall, base of wall condition. A proprietary system of flashing and weeps resides at the bottom of the cells, with mesh inserts to keep mortar from interfering with water exiting the wall through the…