02.010.0401: Sill Detail – Single Wythe Block

02.010.0401: Sill Detail – Single Wythe Block This detail shows an 8” (nominal) split face concrete masonry (CMU) wall, window sill condition. Flashing is provided below the masonry sill, returning vertically at the end termination to form and end dam. Ladder-type horizontal joint reinforcement is placed at 16” o.c. vertically in the wall, or as…

06.130.0204: Floor Tile – Over CBU & Cork on Concrete

06.130.0204: Floor Tile – Over CBU & Cork on Concrete This detail shows tile laid on cementitious backer unit (CBU) w/ taped joints on a concrete subfloor, with cork underlayment separating the tile assembly from the concrete for soundproofing. The tile is adhered to the CBU using a dry-set or latex-modified portland cement mortar bond…