02.010.0401: Sill Detail – Single Wythe Block

02.010.0401: Sill Detail – Single Wythe Block This detail shows an 8” (nominal) split face concrete masonry (CMU) wall, window sill condition. Flashing is provided below the masonry sill, returning vertically at the end termination to form and end dam. Ladder-type horizontal joint reinforcement is placed at 16” o.c. vertically in the wall, or as…

02.410.0132: High Lift Grouting Procedures

02.410.0132: High Lift Grouting Procedures This detail shows a concrete masonry (CMU) wall grouted using high lift grouting procedures. Vertical reinforcement is shown with optional rebar positioners, and vertical bars overlap to achieve sufficient development strength per structural design. Grout is applied vertically in lifts between 5′-0″ and 12′-8″, therefore cleanout openings may be required…

02.410.0131: Low Lift Grouting Procedures

02.410.0131: Low Lift Grouting Procedures This detail shows a concrete masonry (CMU) wall grouted using low lift grouting procedures. Vertical reinforcement is shown with optional rebar positioners, and vertical bars overlap to achieve sufficient development strength per structural design. Grout is applied vertically in lifts not to exceed 5 feet, therefore cleanout openings may not…

02.010.0313: Base of Wall – Single Wythe Block, Proprietary Flashing/Weeps

02.010.0313: Base of Wall – Single Wythe Block, Proprietary Flashing/Weeps This detail shows an 8” (nominal) split face concrete masonry (CMU) wall, base of wall condition. A proprietary system of flashing and weeps resides at the bottom of the cells, with mesh inserts to keep mortar from interfering with water exiting the wall through the…

02.010.0301: Foundation Dowel Alignment

02.010.0301: Foundation Dowel Alignment This detail shows a concrete masonry (CMU) wall in partial longitudinal section. In case the foundation dowels do not coincide with the center of the CMU cells, dowels may be bent 1” laterally for every 6” vertically. Vertical reinforcement overlaps the dowels to achieve sufficient development strength per structural design. Dynamic…

02.010.0312: Base of Wall – Single Wythe Block, Flashing at Inside Face

02.010.0312: Base of Wall – Single Wythe Block, Flashing at Inside Face This detail shows an 8” (nominal) split face concrete masonry (CMU) wall, base of wall condition. There is an interior finish of steel studs and gypsum board, allowing the flashing to return at leaset 8″ vertically and then be anchored to the interior…