This detail illustrates a masonry window head condition. The concrete masonry backing is treated with blocking at the perimeter of the opening, which is wrapped with transition material that engages with the air/moisture/vapor barrier in the field of the wall. This provides continuous resistance to air and moisture. Continuous insulation offers excellent thermal control. An optional cavity drainage insert protects the weep vents at the bottom of the cavity from becoming obstructed.

The detail incorporates a vertical brick expansion joint and a vertical control joint at the block backing. The loose steel lintel is protected with thru-wall flashing returning vertically at each end termination to form an end dam. The durable drip edge guards against moisture reentry and may be notched to avoid excessively thick laps. Firestop material may be used behind the lintel if required by code.

3D Detail

Explore this 3D detail and download the Sketchup model in the 3D Warehouse.


This site uses cookies

Small text files that are placed on your machine to help the site provide a better user experience. In general, cookies are used to retain user preferences, store information for things like shopping carts, and provide anonymised tracking data to third party applications like Google Analytics. As a rule, cookies will make your browsing experience better. However, you may prefer to disable cookies on this site and on others. The most effective way to do this is to disable cookies in your browser. We suggest consulting the Help section of your browser or if you decline you will be redirected to the About Cookies website which offers guidance for all modern browsers.